WHEN
UTILITY IS A MATTER OF SURVIVAL
Tiger's technical team understands your need for a durable, reliable, and low maintenance
device that doesn't require a Ph.D. to operate. With the MTO, we engineered an electro-optic
instrument that can withstand the hard knocks of instrument life. At the same time, we preserved
the extraordinary sensitivity and speed of response associated with laser-based technology.
Designed
for field use, the MTO offers the following unique advantages:
Ease of operation. Ready to use right from the factory, the MTO does not require special skills
to start-up or to utilize its many features. Its menu-driven microprocessor control accesses a
single-branched menu that allows you ready access to all variables, including start-up and shutdown procedures.
Minimal maintenance.
The MTO requires no calibration and very limited maintenance, with no moving parts, no consumables, and
reliance upon a non-contact measurement technique. The MTO works when you need it - the ultimate goal.
Rack-mount configuration.
The MTO-1000's all-in-one box fits into a standard 19" rack, with the capacity to monitor up to four sample
gases at a time.
Insensitivity to
pressure and temperature changes. While non-CRDS absorption spectroscopy must maintain the sample
pressure with extreme accuracy for repeatable results, the MTO requires no such effort. According to the
laws of physics, the MTO is unaffected by changes in the sample line pressure or temperature, based on
the effect known as pressure broadening.
Low power consumption. Thanks to its patented use of Continuous Wave (CW) lasers, the MTO has
low power requirements with no sacrifice in laser lifetime. No pumps, heaters, or ionization sources
are required. The low power consumption of the MTO-1000 makes it suitable for operation on an
Uninterruptible Power Supply (UPS) for continuous monitoring even during power outages.
Freedom from calibration. Because it relies on an absolute measurement principle, the MTO-1000
requires no cumbersome, time-consuming calibration procedures. Indeed, the MTO has a built-in function
to perform a zero check, free of purifiers and costly purified gas. The MTO simply tunes the laser to a
wavelength where no moisture absorption occurs, making the water "invisible". In this mode, the system
can characterize all other sources of signal to serve as a baseline. The MTO then deducts the baseline
from the measurements taken when the laser returns to its absorption peak. The zero check is initiated
manually or programmed to occur at pre-determined intervals, depending on need.
Portability. Built
to sustain mechanical shocks, the MTO is ideal for portable carts in general and transport in particular.
Plus, there's no need to stabilize, reset, calibrate or in any way reconfigure the MTO when you go from
point to point. The unit continues to monitor in real-time, without delay.
Service in real-time.
Tiger Optics offers built-in diagnostic tools for on-line service and maintenance. The MTO constantly
monitors all operating and measurement parameters. System events and faults are logged to the internal
hard drive in the unit. Just provide Tiger Optics with access via the built-in ethernet connection through
the Internet, and we'll check out your system from half-way around the world. Or, simply email us your
diagnostic files. Either way, you stay operational.
|